• +65-82682912

    sales@worldtechnologies.sg

Municipal Solid Waste Treatment

Design Basis

  • Feed Stock: Municipal Solid waste
  • Quantity: 300 tonnes/day
  • Assumptions
  • Non separated mixed waste
  • Organic fraction: 47%
  • Humidity: 50%

Biogas Yield Estimation

Particulars Parameter Quantity
MSW (Un – Separated) TPD 300
MSW (Separated) TPD 140.4
Qty / year TPY 51246
Dry Matter (DM) % 50
Dry Matter (DM) TPD 70.2
Organic Dry Matter (ODM) in DM % 60
Organic Dry Matter (ODM) in DM TPD 35.1
Biogas Yield M³/kg ODM 0.4
Biogas Yield M³/day 14040
Biogas Yield M³/year 5124600

Plant Capacity

Particulars Parameter Quantity
Electric Power KW 140.4
Heat Power KW 51246
Electric Energy KWH/Year 50

Bio Fertilizers

  • Natural Biofertilizer obtained by means of Anaerobic Digestion
  • Rich in Bioactive substances and micro elements.

Composition (kg/ton)

Nr 5.6 – 5.8
NH4 – N 1.6 – 1.9
P2O5 3.2 – 3.6
K2O 4.0 – 4.3
MgO 2.5 – 2.7

Being a trusted waste management company, World Technologies PTE LTD would like to suggest you about off-site remediation. We are here to help you in order to deal effectively with contaminated soils. Technology like bioremediation has made this quite easy as microorganisms are used to break down toxic compounds.

  • Anaerobic Digester
  • COD Reductionand
  • Biogas Generation
  • Manage Alkalinity
  • Consistency ofOperation
  • Gas Holding within Digester
  • Inside tank Mixing Technology
  • SeedSludge/ Wastewater Extraction
  • No Chemical for operation
  • No process water for dilution

Areas of Application

  • Surface Soil Contamination
  • Sub-Surface Soil Contamination
  • Lagoon Contamination
  • Water Contamination

The pollutant can be eradicated from water and soil using microorganism. The motto of this process is making the world free from pollution taking help of environment-friendly microbes.